In-house fabrication of bipolar electrode-cannula assembly for electrical stimulation and drug delivery at the same site in rat brain

dc.contributor.authorChoudhary, Amit G.en_US
dc.contributor.authorAwathale, Sanjay N.en_US
dc.contributor.authorSUBHEDAR, NISHIKANT K.en_US
dc.contributor.authorKokare, Dadasaheb M.en_US
dc.contributor.departmentDept. of Biologyen_US
dc.date.accessioned2022-12-16T10:27:33Z
dc.date.available2022-12-16T10:27:33Z
dc.date.issued2022-12en_US
dc.description.abstractStrategies drawn at understanding the functional attributes of specific neural circuits often necessitate electrical stimulation and pharmacological manipulation at the same anatomical site. We describe a simple, inexpensive and reliable method to fabricate a bipolar electrode-cannula assembly for delivery of electric pulses and administration of neuroactive agents at the same site in the rat brain. The assembly consisting of a guide cannula, dummy cannula, internal cannula and bipolar electrode was fabricated using syringe needles, wires and simple electronic components. To test the usefulness of the device, it was implanted on the skull of a rat specifically targeting the posterior ventral tegmental area (pVTA). The rat was conditioned to press the lever in intracranial self-stimulation (ICSS) protocol in an operant chamber. The number of lever presses in a 30 min task was monitored. Intra-pVTA administration with bicuculline (GABAA receptor antagonist) increased the lever press activity, while muscimol (GABAA receptor agonist) had opposite effect. The results confirm that the group of neurons responding to the electrical stimulation probably receive GABAergic inputs. The device is light in weight, costs less than a dollar and can be fabricated from readily available components. It can serve a useful purpose in electrically stimulating any given target in the brain - before, during or after pharmacological manipulation at the same locus and may find application in neuropharmacological and neurobehavioral studies.en_US
dc.identifier.citationJournal of Pharmacological and Toxicological Methods, 118, 107194.en_US
dc.identifier.issn1056-8719en_US
dc.identifier.issn1873-488Xen_US
dc.identifier.sourcetitleJournal of Pharmacological and Toxicological Methodsen_US
dc.identifier.urihttps://doi.org/10.1016/j.vascn.2022.107194
dc.identifier.urihttp://dr.iiserpune.ac.in:8080/xmlui/handle/123456789/7517
dc.language.isoenen_US
dc.publication.originofpublisherForeignen_US
dc.publisherElsevier B.V.en_US
dc.subjectBipolar electrode fabricationen_US
dc.subjectGuide cannula fabricationen_US
dc.subjectElectrode-cannula assemblyen_US
dc.subjectIntracranial self-stimulationen_US
dc.subjectOperant conditioningen_US
dc.subjectGABAen_US
dc.subjectRewarden_US
dc.subject2022en_US
dc.titleIn-house fabrication of bipolar electrode-cannula assembly for electrical stimulation and drug delivery at the same site in rat brainen_US